MySensors RS485 Gateway — ESPHome Component
An ESPHome external component that bridges a MySensors RS485 bus to a TCP socket (port 5003 by default), allowing Home Assistant or any MySensors controller to communicate with RS485 nodes.
Hardware
Required wiring
| ESP pin | RS485 transceiver |
|---|---|
| UART TX | DI (Driver Input) |
| UART RX | RO (Receiver Output) |
| GPIO (any) | DE + /RE tied together (flow control) |
| 3.3 V / GND | VCC / GND |
Recommended transceivers: MAX485, SP3485, SN75176.
⚠️ DE and /RE must be tied together and driven by a single GPIO. The component will assert this pin HIGH before transmitting and LOW immediately after, returning the transceiver to receive mode.
Installation
Add the component as an ESPHome external component:
external_components:
- source:
type: git
url: https://github.com/JochenFriedrich/mysensors-rs485
ref: master
Minimal YAML example
esphome:
name: mysensors-gw
esp32:
board: esp32dev
framework:
type: arduino
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
logger:
api:
ota:
password: !secret ota_password
# ── SNTP for accurate time sync to nodes ─────────────────────────────────────
time:
- platform: sntp
id: sntp_time
timezone: Europe/Berlin
# ── UART connected to RS485 transceiver ──────────────────────────────────────
uart:
id: rs485_uart
tx_pin: GPIO17
rx_pin: GPIO16
baud_rate: 115200
# RS485 framing: 8N1 (ESPHome default – no need to specify explicitly)
# ── MySensors RS485 gateway ───────────────────────────────────────────────────
mysensors_rs485:
uart_id: rs485_uart
port: 5003 # TCP port the controller connects to
flow_control_pin:
number: GPIO4 # DE / /RE pin of the RS485 transceiver
mode: OUTPUT
Full YAML example (with recommended extras)
esphome:
name: mysensors-gw
friendly_name: MySensors RS485 Gateway
esp32:
board: esp32dev
framework:
type: arduino
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
ap:
ssid: "MySensors GW Fallback"
password: !secret ap_password
captive_portal:
logger:
level: DEBUG
api:
encryption:
key: !secret ha_api_key
ota:
password: !secret ota_password
time:
- platform: sntp
id: sntp_time
timezone: Europe/Berlin
servers:
- 0.pool.ntp.org
- 1.pool.ntp.org
uart:
id: rs485_uart
tx_pin: GPIO17
rx_pin: GPIO16
baud_rate: 115200
mysensors_rs485:
uart_id: rs485_uart
port: 5003
flow_control_pin:
number: GPIO4
mode: OUTPUT
Home Assistant configuration
In your Home Assistant configuration.yaml, add:
mysensors:
gateways:
- device: tcp://192.168.1.XXX:5003
persistence_file: mysensors.json
version: "2.3"
optimistic: false
retain: false
Replace 192.168.1.XXX with the IP address of your ESP device.
Protocol details
The component implements the MySensors v2 serial protocol over RS485 using ICSC framing:
SOH SOH <dst> <src> <cmd=0x58> <len> STX <payload[len]> ETX <crc> EOT
The TCP side uses the standard MySensors ASCII serial protocol:
node-id;child-sensor-id;message-type;ack;sub-type;payload\n
Gateway-handled internal messages
The following MySensors internal messages are handled locally by the gateway and do not require a controller to be connected:
| Sub-type | Description |
|---|---|
I_FIND_PARENT_REQUEST |
Replies with distance=0 (gateway is the parent) |
I_PING |
Replies with I_PONG, echoing the hop counter |
I_ID_REQUEST |
Assigns the next free node ID (1–254) and broadcasts I_ID_RESPONSE |
I_TIME |
Replies with current epoch time (requires SNTP for accuracy) |
I_REGISTRATION_REQUEST |
Replies with I_REGISTRATION_RESPONSE (allowed=1) |
I_VERSION (from controller) |
Replies with gateway firmware version string locally |
All other messages (including I_TIME requests) are also forwarded to the TCP controller.
Configuration options
| Option | Type | Default | Description |
|---|---|---|---|
uart_id |
ID | — | Required. The UART component connected to the RS485 transceiver. |
port |
int | 5003 |
TCP port to listen on. |
flow_control_pin |
pin | — | GPIO driving DE+/RE of the RS485 transceiver. Omit if your hardware uses auto-direction control. |
Troubleshooting
Nodes can't find the gateway
- Check wiring: A/B polarity on the RS485 bus.
- Verify
baud_ratematches your nodes (common: 9600, 57600, 115200). - Enable
logger: level: VERBOSEto see every received byte.
Home Assistant shows nodes as unavailable
- Ensure the TCP port (default 5003) is reachable from HA (no firewall blocking it).
- Check the HA log for MySensors gateway connection errors.
Garbled messages / checksum errors
- Add a 120 Ω termination resistor between A and B at both ends of the bus.
- Reduce baud rate if the cable is long (>10 m).
Nodes don't get a time response
- Add an SNTP
time:component to your ESPHome config. Without it the gateway falls back tomillis()/1000(time since boot), which will cause incorrect timestamps on nodes.
Changes vs original
- Single-byte drain fixed: all available UART bytes are consumed per
loop()call. - TCP split-read fixed: proper line buffer handles fragmented TCP packets.
- Payload encoding fixed:
encode()no longer drops the payload field; correct length is written into the VSL byte. - Float decode fixed: uses
memcpyinstead of pointer cast to avoid UB and misaligned access. - Receive timeout: stale partial packets are discarded after 100 ms.
- Transmit delay: 2 µs hold after asserting DE before releasing to RX.
- Node ID assignment: gateway now handles
I_ID_REQUESTand maintains a bitmap of assigned IDs. - Internal protocol:
I_FIND_PARENT_REQUEST,I_PING,I_REGISTRATION_REQUEST, andI_TIMEare now handled locally. - Version string: defined as constants, not a hardcoded string literal.
- All magic numbers: replaced with named constants from the MySensors v2 spec.
__init__.py: framework version guard added; class name capitalised toMySensorsGW.